The Thermoregulator allows you to manage the heating system in which the fireplace is inserted in a complete and effective way. The multiple choice options for the TC110 plate make the product versatile also in terms of design.
It manages up to 6 system configurations
Through its inputs it is possible to detect:
– System delivery temperature
– System return temperature
– Boiler/DHW storage temperature
– Domestic water withdrawal flow switch consent
Through the outputs it is possible to control the devices present in the system such as:
– System pump
– Recirculation pump / Solenoid valve
– Gas boiler consent.
– Service
Diet | 230/115Vac 50/60Hz |
Fuse | T 3.15A |
N.02 Entrances | Temperature probe sensor, Flow switch |
Measuring range Temperature | -40 ÷ 120 /260 °C |
N. 04 Max Controlled Outputs | On/Off 5A 250 Vac |
Output typology | free contacts / Powered 230 Vac |
Mechanical dimensions | 3 built-in/wall modules |
Cover plate | TiEmme, Vimar, Ave |